| ULTRA JACKET series 150T and 200T.
Temperature rating: to 250ºF continuous
Applications: Freeze protection and low temperature applications where insulation and heating may be required
|
| Outer and Inner Fabric: |
SIL-GLASS silicone coated and impregnated fiberglass, weight: 18 oz/sq yd or TEF-GLASS PTFE coated and impregnated fiberglass, nominal weight 17 oz/sq yd |
| Insulation: | TEMP-FOAM 10, nonhydroscopic cross linked polyfoam 150T = 1/2" thickness 200T = 1" thickness |
| ULTRA JACKET series 550.
Temperature rating: to 550ºF continuous
Applications: Flowmeters, level gages, valves, flanges, pumps, etc.
|
 |
| Outer and Inner Fabric: |
Outer and inner fabric is TEF-GLASS PTFE coated and impregnated fiberglass nominal weight, 17 oz/sq yd |
| Insulation: |
GLASS-MAT 10, 1" needled fiberglass mat with no resins or binders, 15 oz/sq ft., K factor = 0.39 at 300ºF |
| ULTRA JACKET series 800.
Temperature rating: to 800ºF continuous
Applications: Flowmeters, level gages, valves, flanges, pumps, etc.
|
 |
Outer fabric is TEF-GLASS 17 Insulation - 2# fiberglass boardShown with lacing hook on right, quilting pin on left |
| Outer Fabric: |
TEF-GLASS PTFE coated and impregnated fiberglass, nominal weight 17 oz/sq yd |
| Inner Fabric: |
FIBERGLASS 19 uncoated fiberglass fabric, nominal weight 19 oz/sq yd |
| Insulation: |
GLASS-MAT 20, 2" fiberglass board, 3 lb density, K factor = 0.39 at 300ºF |
| ULTRA JACKET series 1000.
Temperature rating: to 1000ºF continuous
Applications: High temperature applications for valves, flanges, heat exchangers, pumps and other pipeline items
Shown with lacing hook on left, quilting pin on right
|
| Outer Fabric: |
TEF-GLASS PTFE coated and impregnated fiberglass, nominal weight 17 oz/sq yd |
| Inner Fabric: |
FIBERGLASS 19 uncoated fiberglass fabric, nominal weight 19 oz/sq yd |
| Insulation: |
GLASS-MAT 30, 3" fiberglass board, 3 lb density, K factor = 0.39 at 300ºF |
|